Installation
2.Iftheinlet󰘱uidpressuretothepumpismore
than25%oftheoutletworkingpressure,the
ballcheckvalveswillnotclosefastenough,
resultingininef󰘰cientpumpoperation.Excessive
inlet󰘱uidpressurealsowillshortendiaphragm
life.Approximately3–5psi(0.02–0.03MPa,
0.21–0.34bar)shouldbeadequateformost
materials.
3.Formaximumsuctionlift(wetanddry),see
TechnicalData,page22.Forbestresults,always
installthepumpascloseaspossibletothe
materialsource.Minimizesuctionrequirements
tomaximizepumpperformance.
Fluid Fluid
Fluid
Outlet Outlet
Outlet
Line Line
Line
1.Usegrounded,󰘱exible󰘱uidhoses.See
GroundTheSystem,page10,
2.Installa󰘱uiddrainvalve(F)nearthe󰘱uidoutlet.
3.Installashutoffvalve(G)inthe󰘱uidoutletline.
12
3A2578E