Appendix A - ADM
114 3A2347ZAA
Setup Screens
NOTE: It is important to set all settings in the System
screens correctly to ensure optimal system perfor-
mance.
Password
If the password is not ā0000ā, the password must be
entered to access the setup screens.
System 1
A PLC can be used to control or monitor the system.
See PLC Connection on page 23 for instructions.
System 2
Use this screen to enable the installed channels and
specify the type of gun RTD type used. See Select
ADM Settings on page 20.
System 3
System Type: Choose the model of the system. Older
versions of software may not have this option.
Enable Diagnostic Screen: Choose whether to hide
the Diagnostic screen.
Pump Idle Time to System Inactive: The heating sys-
tem will be disabled after the pump has been idle for the
set amount of time
Power Type: Select the system power type.
Circuit Breaker Size: Select the circuit breaker size.
Refill Setting: To use the automatic vacuum transfer,
select Auto. To disable the automatic vacuum transfer,
select Manual. The main reason to disable automatic
refill is while flushing. However, if an issue is present
with the automatic refill system that cannot be solved in
a timely manner, manual refill can be used to return the
system to service. See Manual Refill on page 30.
See Select ADM Settings on page 20.
System 4
Enable ADM Unit Counter: Select to enable ADM
counting of units using an external sensor.
Enable material Alerts: Select to enable record only
events indicating low/high material usage.
Specific Gravity: Required to convert the volume dis-
pensed to mass dispensed for tracking the total weight
and flow rate.