Setup
3A2347ZAA 27
Calibration
Perform the following steps to calibrate the material
tracking function:
1. Navigate tj the material Tracking Screen (Screen 4
of the System chapter).
2. To calibrate using the tape and scrape method:
a. Obtain a scale.
b. Place tape on a procudt(s) in locations where
material is dispensed.
c. Run normal production (un-taped products) until
a value appears in the grams per product label
(this could take several minutes of production).
d. Run taped products(s) through line and allow
material to cool and harden on the tape.
e. Scrape all material from product and place on
scale.
f. Adjust the specific gravity setting until the grams
per product displayed matches the value mea-
sured by the scale using the following formula:
New SG Value = Current SG Value x Measured Grams
per Product / Displayed Grams per Product
3. To calibrate using the purge method:
a. Obtain a scale and a container.
b. Reset the calibration weight totalizer by press-
ing and holding the reset softkey .
c. Tare scale with empty container and purge at
least 1 lb. of material into the container.
d. Weigh container with material.
e. Adjust the specific gravity setting until the
weight displayed in the totalizer matches the
value measured by the scale using the following
formula:
New SG Value = Durrent SG Value x Measured Weight /
Displayed Weight