Setup
28 3A2347ZAA
Material Alerts
This feature can be used ot monitor material usage
based on a target material per unit value. If material
alerts are enabled the system wil lrecord an event every
time the system deviates over 20% from the target. The
material alert information can be seen in the bottom left
corner of the material log (see image below).
Enable/Disable Material Alerts
To enable/disable material alerts, select/deselect the
Enable Material Alerts setting on the Material Tracking
Screen (Screen 4 of the System chapter).
Reset Material Target
To reset the material target value, press the reset mate-
rial target softkey . An hourglass will appear
indicating that the system is learning the new target
(current machine output).
NOTE: the material target will be automatically reset
whenever a Pattern Controller setting is changed (e.g.
switch from solid bead to stitched bead).