Troubleshooting
Problem Problem
Problem
Cause Cause
Cause
Solution Solution
Solution
Aand/orBheatersareoverheating
material.
Checkprimaryheatersforeither
anRTDproblemorafailed
elementattachedtoRTD,see
ElectricalSchematics,page102.
FaultyFTSconnections.VerifythatallFTSconnectionsare
snugandthatpinsofconnectors
areclean.Unplugandre-plug
RTDwires,cleaningoffanydebris.
Ambienttemperatureistoohigh.
Coverhosesormovetoalocation
withalowerambienttemperature.
HoseinsulationovertheFTS
locationisdamaged.
Replacedamagedinsulation.
Hosetemperatureexceeds
setpoint.
IfHoseResistanceModeis
enabled,thecalibrationfactormay
beinaccurate.
Re-calibratethehose.Followthe
CalibrationProcedure,page65.
FaultyFTSconnections.VerifythatallFTSconnectionsare
snugandthatpinsofconnectors
areclean.Unplugandre-plug
FTSwiresalonglengthofhose,
cleaningoffanydebris.
FTSnotinstalledcorrectly.FTSshouldbeinstalledcloseto
endofhoseinsameenvironment
asgun.VerifyFTSinstallation,
seeRepairFluidTemperature
Sensor(FTS),page64.
Erratichosetemperature.
Missingordamagedinsulation
aroundFTS,causingthehose
heattobeONconstantly.
Makesurethehosebundle
hasadequateinsulationevenly
coveringtheentirelengthand
connectionjoints.
FTSfailed.CheckFTS,seeRepairFluid
TemperatureSensor(FTS),page
64.
FTSnotinstalledcorrectly.FTSshouldbeinstalledcloseto
endofhoseinsameenvironment
asgun.VerifyFTSinstallation,
seeRepairFluidTemperature
Sensor(FTS),page64.
Loosehoseelectricalconnections.
Checkconnections.Repairas
necessary.
Circuitbreakerstripped.Resetbreakers(CB11and/or
CB15),seeRepairCircuitBreaker
Module,page66.
Hosezonenotturnedon.Turnonhoseheatzone.
Hosedoesnotheat.
AandBtemperaturesetpointstoo
low.
Check.Increaseifnecessary.
334946H 43