CE5000-UM-251-9370 3-1
3 OPER ATIONS
3 OPERATIONS
3.1 Control Panel
Indicator Lamp
STATUS ����� Illuminates while the power to the cutting
plotter is turned on, and goes out when
the cutting plotter is in PAUSE status�
This lamp flashes when data is being
received from an interface, regardless
of whether or not the cutting plotter is in
PAUSE status�
Panel Keys
TEST ����������Press this function key to conduct
a cutting test and check the cutting
conditions�
PREV� ��������Press this function key to view the
previous display on the LCD when in
PAUSE status�
NEXT ���������Press this function key to view the next
display on the LCD when in PAUSE
status�
COND� �������Press this function key to view the cutter-
pen condition settings�
PAUSE �������Press this function key once in READY status to switch to PAUSE status in order to change
the various settings� Press it again to cancel the PAUSE status� Pressing this key while
cutting or plotting is in progress stops the cutting or plotting�
ENTER�������Pressing this function key registers the cutting or plotting conditions set�
POSITION �These keys are used to move the cursor or change the settings on the LCD display on the
function setting screens� Press these keys when in PAUSE status to move the pen carriage
or the medium�
ORIGIN ������Press this function key to set the origin point� The pen position is set as the origin point when
this key is pressed�