3-81
CHAPTER 3 Settings and Measurement
Setting Selections available
Data search CH CH1 to 10, Logic, Pulse, Alarm
* Logic and Pulse are displayed only if the Logic Pulse
function is On in the AMP settings.
[CH1 to CH10]•WL CH1-10 , WL1-8
[Logic] Logic1-8
[Pulse] Pulse1-8
[Alarm] Alarm1-4, WL1
Mode [CH1 to CH10]•WL
H,
L
[Logic]
H,
L
[Pulse]
H,
L
[Alarm] Both,
H,
L
Level [CH1 to CH10]•WL Set numeric value
[Pulse] Set numeric value
Find Next Press right key to execute.
Find Previous Press right key to execute.
Statistical
calculation
between cursors
Function Off, Average, Max, Min, Peak, RMS
Execute Press right key to execute.
(10)-1 Move to First Data
Executing this option moves the currently selected cursor (A or B) to the start of the data.
(10)-2 Move to Last Data
Executing this option moves the currently selected cursor (A or B) to the end of the data.
(10)-3 Move to Center
Executing this option moves the currently selected cursor (A or B) to the center of the data.
(10)-4 Move to Selected Position
Sets a position (relative position in time) or time and moves the currently selected cursor (A or B) to this
position or time.
<If the Method is Position> <If the Method is Time>
(1)
(2)
(1)
(3)
Setting Selections available
(1) Method Sets the method for specifying the position to move the cursor.
Select Position or Time.
(2) Position Sets the position to move the cursor. The cursor can be set from the capture start position
assumed as the Start Point 0s up to the end point value.
(3) Time Sets the date and time to move the cursor. The cursor can be set from the capture start
position assumed as the Start Point date/time up to the end point value.
(10)-5 Cursor Sync
Sets up the function that moves two cursors in synchronization.
Selection item Description
Off Cursors are not synchronized. Only the specied one cursor moves.
On Two cursors move in synchronization. Cursor A is always the fulcrum.
* Cursor Synch is turned Off when you move a cursor using Move to Selected Position or perform Data Search.