EasyManua.ls Logo

GRAPHTEC midi LOGGER GL240 - 2.6 Logic Alarm Cable Setup

GRAPHTEC midi LOGGER GL240
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-7
CHAPTER 2 Checks and Preparation
2.6 Logic Alarm Cable Connection and Functions
This section describes how to connect the logic alarm cables and the functions of cable.
During wiring, conrm that the signal's supply source is turned OFF to prevent electrical shocks.
Also, position the GL240 input cable away from any power lines and ground cables.
The Input/output cable for GL (B-513: Option) enables logic/pulse input, external trigger input, and alarm
signal output.
Connect the Input/output cable for GL (B-513: Option) to the external input/output terminal as shown below.
Input/output cable for GL
(B-513: Option)
Logic/Pulse Input Specications
Item Description
Number of input channels 4
Input voltage range 0 to +24V max. (single-ended ground input)
Threshold level Approx. +2.5V
Hysteresis Approx. 0.5 V (+2.5 to +3 V)
* Switch between logic and pulse input.
Trigger Input/External Sampling Input Specications
Item Description
Number of input channels 1
Input voltage range 0 to +24V max. (single-ended ground input)
Threshold level Approx. +2.5V
Hysteresis Approx. 0.5 V (+2.5 to +3 V)
Alarm Output Specications
Item Description
Number of Output channels 4
Output format Open collector output
+5 V, 10 KΩ pull-up resistance
* See the next page for details on alarm output
When the power is turned OFF or ON, the GL240 temporarily becomes the alarm state.