Multi-VRF Centralized Controller
19
water tank or hot water generator will start up in this period, and will decide the on
and off of water tank or hot water generator according to the temperature difference
between actual water temperature and the setting water temperature. If it is not
within this period, the water tank or hot water generator will close down the unit.
Once this mode is set, it will circularly operate every day.
3
Temperature Setting
It displays the current temperature of hot water as default. The temperature
value will turn to the setting temperature and can be adjusted by pressing
and buttons; the temperature value will increase or decrease by every
pressing the button for once. The temperature value will be continuously increased
or decreased by long pressing the button.After 5 seconds without any action, the
temperature value will turn back to the current temperature.
Under the standard HotWater, Booking and Night modes, the temperature
setting range is: 35
℃~
the maximal adjustable temperature 55
, the acquiescence
maximal temperature is 50
.
4
Available Hot Water Volume
The water volume can be display in real time, there are five sections of water
volume: 100%, 80%, 60%, 40%, 20%, when the water volume is less than 20%, it
will flicker.
5
Function Setting of Water Heating
Under on /off status of water heating, the following functions can be set:
Water On/Off
Functions
Start-up Water mode
Sunflower, Auto, Sterilization, Fast, Shield
Start-up Booking mode
Auto, Sterilization, Fast, Shield
Start-up Night mode
Auto,Sterilization, Fast, Shield
Water heating off
Sterilization
Sunflower function: find the highest outdoor temperature by recording the
history data of outdoor temperature to define the time to heat the water, so as to
achieve energy saving.
Auto function: the setting temperature of water heating will be automatically
provided by water heater according to the outdoor ambient temperature, there is no
need to set by the user, and the water temperature cannot be adjusted via or
buttons.
Sterilization function: it will conduct high temperature sterilization when the
water temperature in the water tank is heated to 65~70
(adjustable) within the