DC INVERTER MULTI VRF MAINTENANCE
213
6Loosen the
fixing screw of
motor cover
Loosen the fixing
screw of motor cover
with screwdriver
7. Remove
motor cover
subassembly
Remove motor
cover subassembly
8. Loosen the
screw fixing
motor and
motor shaft
Rotate the cross flow
blade to make the
screw upward.
Loosen the screw
with screwdriver.
9. Replace the
motor
Remove the motor
and mount a new one
10. Mount the
motor cover
subassembly
and tighten the
screw
Mount the motor
cover subassembly
and tighten the fixing
screw of motor cover
and cross flow blade.