DC INVERTER MULTI VRF MAINTENANCE
z Wall-mounted Unit
Removal and Wall-mounted Unit Assembly of Fan Motor
Remarks: Before removing the compressor, make sure that there is no refrigerant inside the pipe system and
that the power has been cut off.
Step Illustration Handling Instruction
1. Firstly,
remove
the front
panel,
front case
and
electric
box
●Firstly, use
screwdriver to loosen
the screws.
●Unplug the motor
terminals in the electric
box. Loosen the earth
screws and lift up.
2. Remove
the
evaporator
●Firstly, use
screwdriver to remove
the fixing screws on the
left and right side. Then,
remove the evaporator.
3. Remove
the motor
and cross
flow fan
●Use screwdriver to
remove the screws
fixing the motor clamp
and remove the screws
connecting the motor
and cross flow fan.
Then, the motor can be
separated from the
cross flow fan.
Screw