Unit Control
50
unadjustable
2. When "Floor config" is set to
"Without", this function is adjustable.
5
Cool+hot
water
Cool+hot water
Cool/Hot water
Cool
When the water tank is unavailable,
this function will be reserved, and
the LCD will display ‘Reserved’.
6
Heat+hot
water
Heat+hot water
Heat/Hot water
Heat
When the water tank is unavailable,
this function will be reserved, and
the LCD will display ‘Reserved’.
7
Quiet mode
Quiet mode
On/Off
Off
/
8
Quiet timer
Quiet timer
On/Off
Off
/
9
Weather-dep
endent mode
Weatherdepend
On/Off
Off
/
10
Holiday
release
Holiday release
On/Off
Off
/
11
Disinfection
Disinfection
On/Off
Off
When the water tank is unavailable,
this function will be reserved, and
the LCD will display ‘Reserved’.
12
Weekly timer
Weekly timer
On/Off
Off
/
13
Clock timer
Clock timer
On/Off
Off
/
14
Temperature
timer
Temp. timer
On/Off
Off
/
15
Solar kit
Solar kit
On/Off/Timer
Off
When the water tank is unavailable,
this setting will be reserved. If it is
set to “On”, the solar kit will function
no matter if the timer is activated or
not; if it is set to “Off”, the solar
heating function is unavailable; if it is
set to “Timer”, the solar kit can
function when the timer has been
activated.
16
Floor debug
Floor debug
On/Off
Off
/
17
Emergency
mode
Emergen. mode
On/Off
Off
/
18
Holiday mode
Holiday mode
On/Off
Off
/
19
Thermostat
Thermostat
Air/Without/
Air+hot water
Without
This setting cannot be changed from
“Air” to “Air+hot water” directly but
via “Without” this option and the unit
will go to Without status. Meanwhile,
the control will send out “Without”
command for consecutive 40
seconds (it is longer than the
communication error, and the “On”
command can be performed only
when 40 seconds have been