Unit Control
51
expired.
When it set to “Air+hot water”, “hot
water” can be performed even
though the thermostat is off.
20
Assistant
heater
Assis. Heater
1/2/Off
Off
/
21
Other heater
Other heater
With/Without
Without
/
22
Chassis
heater
Chassis heater
On/Off
On
/
23
Tank heater
running
Tank heater
On/Off
Off
When the water tank is available,
this setting is adjustable; when it is
unavailable, it will be reserved.
When it is set to be “Off” and the
solar kit is available, the water tank
temperature will be adjustable; when
the solar kit is unavailable, the upper
limit of the water tank temperature
should be set to 50
.
24
Solar
kit-antifreeze
Solar antifre
On/Off
Off
25
Water tank
Water tank
With/Without
Without
/
26
Tank sensor
Tank sensor
1/2
2
When the water tank is unavailable,
this function will be reserved. and
the LCD will display ‘Reserved’.
27
Solar heater
Solar heater
With/Without
Without
/
28
Floor config
Floor config
With/Without
With
Under the heating mode, if it is set to
“With”, the setting value is defaulted
to be the normal water temperature
and cannot be adjusted; if it is set to
“Without”, the setting value can be
changed freely.
Under the cooling mode, if it is set to
“With”, the leaving water
temperature range will be 18- 25
and 18
is the default. When it is
set to “Without”, the leaving water
temperature range will be 7-25
and 7
is the default. This setting is
unavailable when the unit is
stopped.
29
Remote
sensor
Remote sensor
With/Without
Without
When it is set to “Without”, the
“Control state” will be automatically
changed to “T-water out”.

Table of Contents