Unit Control
62
Solar timer
”.
[Notes]
Once
Solar timer
” is activated,it cannot be deactivated through ON/OFF operation but be done
manually.
Start time
” and “
End time
” will be memorized upon power failure
It can be set under both ON and OFF states
3. 2.2.16 Floor Debug
This function will make the unit to perform periodic preheating to the floor for the initial run once floor
coils have been installed.
[Operation Instructions]
1. At the homepage, by pressing the
Function
key access to the
FUNCTION
page, and then
locate where
Floor debug
is, after that, press
OK
key to go to the
FLOOR DEBUG
setting
page.
2. At the
FLOOR DEBUG
setting page, by the
Left/Right
key select the desired
parameter and then by the
Up/Down
key configure it. The configurable parameters
include “
Segments
”, “
Period 1 temp
”, “
ΔT of segment
”, and “
Segment time
”, as listed in the following
table.
No.
Full Name
Displayed Name
Range
Default
Accuracy
1
Segments for floor debug
Segments
1~10
1
1
2
First temperature for floor debug
Period 1 temp
25~35°C/77~95°F
25°C/77°F
1°C/1°F
3
Segment temperature difference for
floor debug
ΔT of segment
0~72H
0
12H
4
Segments duration for floor debug
Segment time
2~10°C/36~50°F
5°C/41°F
1°C/1°F
3. After the above setting is finished, by pressing the function key no.2 activate this function
and a dialog box will pop up, reminding “
Start the Floor Debug Mode now?
”. If so, press the “
OK
” key
. Once “
Floor debug
” has been activated, by pressing the
function
key no.2 , a dialog box
also will pop up, reminding “
Stop the Floor Debug Mode now?
” If so, press the
OK
key ; if not,

Table of Contents