Unit Control
74
[Notes]
The real-time error will show on the control. Taking Error 2 in the above figure for example,
when it is recovered, it will disappear and be replaced by Error 3, and other errors follow the
same way.
If the total no. of errors exceed six, other errors should be viewed by switching pages through
Last
and “
Next
.
Any one among
IDU auxiliary heater 1 error
”,
IDU auxiliary heater 2 error
”,
Water tank
heater error
” occurs, the control will beep until this error has been cleared.
See the following table for error description.
No.
Full Name
Displayed Name
Error Code
1
Ambient temperature sensor error
Ambient sensor
F4
2
Defrost temperature sensor error
Defro. sensor
d6
3
Discharge temperature sensor error
Disch. sensor
F7
4
Suction temperature sensor error
Suction sensor
F5
5
Outdoor fan error
Outdoor fan
EF
6
Compressor internal overload protection
Comp. overload
H3
7
High pressure protection
High pressure
E1
8
Low pressure protection
Low pressure
E3
9
High discharge protection
Hi-discharge
E4
10
Refrigerant loss protection
Refri-loss
P2
11
Heat pump-water pump protection
HP-pump
E0
12
Solar kit-water pump protection
SL-pump
EL
13
Swimming pool-water pump protection
Swimming-pump
14
Incorrect capacity DIP switch setting
Capacity DIP
c5
15
Communication error between indoor and outdoor unit
ODU-IDU Com.
E6
16
Drive communication error
Drive com.
17
High pressure sensor error
HI-pre. sens.
Fc
18
Refrigerant liquid line temperature sensor error
Temp-RLL
F1
19
Refrigerant gas line temperature sensor error
Temp-RGL
F0
20
Heat exchanger-leaving water temperature sensor error
Temp-HELW
F9
21
Auxiliary heater-leaving water temperature sensor error
Temp-AHLW
dH
22
Heat exchanger-entering water temperature sensor error
Temp-HEEW

Table of Contents