GRISWOLD PUMP COMPANY Appendix Page 41
Installation, Operation and Maintenance Manual
Griswold Model 811
Griswold Pump Company Appendix Page 43
Never mix greases of different consistencies or different types.
For re-greaseable bearings:
Lubricating Grease Requirements
Pumpage temperature
< 350
0
F
Pumpage temperature
> 350
0
F
NGLI Consistency 2 3
Mobil Mobilux EP2 SCH32
Exxon Unirex N2 Unirex N3
Sunoco Multipurpose 2EP
SKF LGMT 2 LGMT 3
Re-grease bearings every 2000 hours or three (3) months, whichever occurs first