6.5 "Control mode"
5.1.2.3 Setting to maximum speed
The motor must not be in operating mode Stop.
Press and hold the Up button until the top light field is on and starts flashing.
H
Q
TM054896
5.1.2.4
Setting to minimum speed
The motor must not be in operating mode Stop.
Press and hold the Down button until the bottom light field is on and starts flashing.
H
Q
TM054897
5.1.2.5
Starting the motor
How you start the motor depends on how it was stopped.
Start the motor in one of the following ways:
- If the motor was stopped by pressing the Start/Stop button: Start the motor by pressing the Start/Stop button.
- If the motor was stopped by pressing and holding the Down button: Start the motor by pressing and holding the Up button.
5.1.2.6
Stopping the motor
Stop the motor in one of the following ways:
- Press the Start/Stop button.
- Press and hold the Down button until all light fields are off.
- Use Grundfos GO Remote.
- Use a digital input set to External stop.
5.1.2.7
Resetting alarms and warnings in products with a standard operating panel
You can reset a fault indication in one of the following ways:
- Briefly press the Up or Down button.
This is not possible if the buttons have been locked.
This does not change the setting of the motor.