4.5 Filling of motor liquid
1. Place the motor in vertical position with an inclination of approx. 10°.
2. Remove the filling plug using a screwdriver or a similar tool.
3. Inject motor liquid into the motor with a filling syringe or the like.
4. To allow possible air to escape, move the motor from side to side.
5. Refit the filling plug and make sure that it is tight.
6. The motor is now ready for installation. Fit the pump to the motor, see section 4.2.2
Assembly.
TM01 1434 4597
Fig. 9. Max tilt angel af the motor, when filling in motor liquid.