Analog output (AO)
Current sourcing capability only.
Voltage signal:
Range: 0-10 VDC.
Minimum load between AO and GND: 1 kΩ.
Short-circuit protection: Yes.
Current signal:
Ranges: 0-20 and 4-20 mADC.
Maximum load between AO and GND: 500 Ω.
Open-circuit protection: Yes.
Tolerance: - 0/+ 4 % of full scale (max-point coverage).
Screened cable: 20-16 AWG (0.5 - 1.5 mm
2
).
Maximum cable length: 1640 ft (500 m)
Pt100/1000 inputs (PT)
Temperature range:
Minimum -22 °F (-30 °C) (88 Ω/882 Ω).
Maximum 356 °F (+180 °C) (168 Ω/1685 Ω).
Measurement tolerance: ± 2.7 °F (1.5 °C).
Measurement resolution: < 0.54 °F (0.3 °C).
Automatic range detection (Pt100 or Pt1000): Yes.
Sensor fault alarm: Yes.
Screened cable: 20-16 AWG (0.5 - 1.5 mm
2
).
Use Pt100 for short wires.
Use Pt1000 for long wires.
LiqTec sensor inputs*
Use Grundfos LiqTec sensor only.
Screened cable: 20-16 AWG (0.5 - 1.5 mm
2
).
Power supplies (+5 V, +24 V)
+5 V:
Output voltage: 5 VDC - 5 %/+ 5 %.
Maximum current: 50 mADC (sourcing only).
Overload protection: Yes.
•Sensor.
+24 V:
Output voltage: 24 VDC - 5 %/+ 5 %.
Maximum current: 60 mADC (sourcing only).
Overload protection: Yes.
Digital outputs (relays)
Potential-free changeover contacts.
Minimum contact load when in use: 5 VDC, 10 mA.
Screened cable: 20-12 AWG (0.5 - 2.5 mm
2
).
Maximum cable length: 1640 ft (500 m)
Bus input
Grundfos GENIbus protocol, RS-485.
Screened 3-core cable: 20-16 AWG (0.5 - 1.5 mm
2
).
Maximum cable length: 1640 ft (500 m)
29. Other technical data
EMC (electromagnetic compatibility)
EN 61800-3.
Residential areas, unlimited distribution, corresponding to
CISPR 11, class B, group 1.
Industrial areas, unlimited distribution, corresponding to
CISPR 11, class A, group 1.
Contact Grundfos for further information.
Enclosure class
Standard: IP55 (IEC 34-5).
Optional: IP66 (IEC 34-5).
Insulation class
F (IEC 85).
29.1 Torques
29.2 Sound pressure level
The sound pressure level will be below 70 dB
30. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company
or service workshop.
The waste battery should be disposed of through the local
collective services. If in doubt, contact your local Grundfos
company.
Subject to alterations.
Terminal Thread size
Max. torque
[lbf-ft (Nm)]
L1, L2, L3, L, N M4 1.3 (1.8)
NC, C1, C2, NO M2.5 0.4 (0.5)
1 to 26 and A, Y, B M2 0.4 (0.5)