It is possible to send commands through the serial port to perform specific tasks.
Table 3-17: Single Keystrokes
Hex Decimal Symbol
Percent
equivalent
Master /
Remote
Action
0 0 NULL none M
As part of an echo used to indicate character
information starting at 1
st
of 10 characters
1 1 SOH none M
As part of an echo used to indicate character
information starting at 2
nd
of 10 characters
2 2 STX none M
Used to begin an echo OR as part of an echo used
to indicate character information starting at 3
rd
of 10
characters
3 3 ETX none M
Normally to end an echo OR as part of an echo used
to indicate character information starting at 4
th
of 10
characters
4 4 EOT none M
As part of an echo used to indicate character
information starting at 5
th
of 10 characters.
5 5 ENQ none M
As part of an echo used to indicate character
information starting at 6
th
of 10 characters.
6 6 ACK none M
As part of an echo used to indicate character
information starting at 7
th
of 10 characters.
7 7 BEL none M
As part of an echo used to indicate character
information starting at 8
th
of 10 characters.
8 8 BS none M
Backspace OR as part of an echo used to indicate
character information starting at 9
th
of 10 characters.
9 9 HT none M
As part of an echo used to indicate character
information starting at 10
th
of 10 characters.
A 10 LF none M
As part of an echo used to indicate numeric display
information.
D 13
CR or
CTL-M
none M
Clear Key (clears user input or can initiate an
action). As part of an echo used to indicate
annunciator & display toggle scheme information.
11 17 CTL-Q none M/R Xon
13 19 CTL-S none M/R Xoff
81 129 %[Ctrl-A] M Target Key
85 133 %[Ctrl-E] M Start Key
86 134 %[Ctrl-F] M Stop Key
95 149 %[Ctrl-U] M Echo display (all 3 lines) out comm. 1
96 150 %[Ctrl-V] M Echo display (all 3 lines) out comm. 2
B9 185 %9 M
Enters the number before the %9 as the piece
weight
D0 208 %P M Pause
D0 208 %Q M Send out transmits one and two
D2 210 %R M Remote Key 2
E0 224 %’ M Backward Select
E3 227 %c M Clear Key (clears user input or can initiate an action
E5 229 %e M Enter Key
E9 233 %i M ID Key (Print & Units on 370)
EF 239 %o M/R Turn off 370
F0 240 %p M Print Key/ Arrow Up Key
F2 242 %r M Remote Key 1
F3 243 %s M Select Key
F4 244 %t M Tare Key
F5 245 %u M Units Key/ Right Arrow Key
F6 246 %v M/R Enter Setup
F8 248 %x M [Print][Select] Keys - Extended Resolution Gross
FA 250 %z M Zero Key