EasyManuals Logo

GSM Power Socket User Manual

GSM Power Socket
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
GSM POWER SOCKET USER MANUAL
28
3.7.2 Temperature rapid-changing alarm
Description
A time period value and temperature changing value can be pre-set
onto the socket. In this case, if the surroundings temperature change
to the pre-set value within the pre-set time period, a SMS alarm
message will be auto-sent to masters mobile phone.
This feature depends on the temperature sensor.
Method
The Master user sends following SMS message in order to:
Enable the temperature rapid changing alarm: #160#1# (27)
Set time period and temperature changing value:
#160#Temp#Time# (28)
Temp: The values lie in the range of 1 to 50 centigrade degree.
Time: The values lie in the range of 1 to 300 minutes.
Default Temp is 2 degree and Time is 1 minute.
Disable the temperature rapid changing alarm: #160#0# (29)
Successful SMS reply
Fast temperature changing.: function ON/OFF
Delta:**
Time:* minutes
3.8 SMS notification upon the socket output changing
Description
GSM Power Socket will default notify the user when the state of the
socket output is changed with a SMS notification. The Master user
can enable/disable this SMS notification.
Method
The Master user sends following SMS message in order to:
SMS notification upon the socket output changing (Default):
#11#1# (30)
No SMS notification upon the socket output changing:
#11#0# (31)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GSM Power Socket and is the answer not in the manual?

GSM Power Socket Specifications

General IconGeneral
BrandGSM
ModelPower Socket
CategorySwitch
LanguageEnglish