3.7.2 Temperature rapid-changing alarm
Description
A time period value and temperature changing value can be pre-set
onto the socket. In this case, if the surroundings temperature change
to the pre-set value within the pre-set time period, a SMS alarm
message will be auto-sent to master’s mobile phone.
This feature depends on the temperature sensor.
Method
The Master user sends following SMS message in order to:
Enable the temperature rapid changing alarm: #160#1# (27)
Set time period and temperature changing value:
#160#Temp#Time# (28)
Temp: The values lie in the range of 1 to 50 centigrade degree.
Time: The values lie in the range of 1 to 300 minutes.
Default Temp is 2 degree and Time is 1 minute.
Disable the temperature rapid changing alarm: #160#0# (29)
Successful SMS reply
Fast temperature changing.: function ON/OFF
Delta:**
Time:* minutes
3.8 SMS notification upon the socket output changing
Description
GSM Power Socket will default notify the user when the state of the
socket output is changed with a SMS notification. The Master user
can enable/disable this SMS notification.
Method
The Master user sends following SMS message in order to:
SMS notification upon the socket output changing (Default):
#11#1# (30)
No SMS notification upon the socket output changing:
#11#0# (31)