REMOTE CONTROL
129
Note
About CH3 of GPP-3323, The OVP value can not be
set.
Command
:OUTPut[1|2|3|4]:OVP?
Function
Queries the OVP voltage level.
Example
:OUTPut2:OVP?
Queries the OVP voltage level on CH2.
Note
About CH3 of GPP-3323, OVP query value is 5.5V.
Command
:OUTPut[1|2|3|4]:OCP:STATe <b>
Function
Turns OCP protection on/off
Description
<b>
0/OFF:Turns OCP off.
1/ON:Turns OCP on.
Example
:OUTPut2:OCP:STATe ON
Turn on OCP on CH2.
Command
:OUTPut[1|2|3|4]:OCP:STATe?
Function
Queries the status of the OCP function.
Example
:OUTPut2:OCP:STATe?
Returns the status of the OCP function on CH2.
Command
:OUTPut[1|2|3|4]:OCP:TRIGer?
Function
Query whether the OCP protection function has
been triggered.
Example
:OUTPut2:OCP:TRIGer?
Return whether the OCP protection function of
channel 2 has been triggered.