REMOTE CONTROL
139
Example
:DELAy2:GROUPs 100
Sets the output number of Delay as 100 for CH2.
Command
:DELAy[1|2]:GROUPs?
Function
Queries the output number of Delay.
Example
:DELAy2:GROUPs?
Return the output number of Delay for CH2.
Command
:DELAy[1|2]:PARAmeter <No>,{ON|OFF},<time>
Function
Sets the delay parameter of Delay.
Description
<No> 0-2047 Sets the serial number of delay
parameter. Integer 0-2047
{ON|OFF} The output state of the group
<time> 1s-300s The delay duration of the group.
Integer 1s-300s
Example
:DELAy2:PARAmeter 1,ON,10
Sets the delay parameter of Delay as the 1st group,
output ON, delay 10s for CH2.
Command
:DELAy[1|2]:PARAmeter? <No>[,<count>]