EasyManuals Logo

GW Instek GPP-3323 User Manual

GW Instek GPP-3323
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
GPP Series User Manual
154
Command
:RECOrder[1|2|3|4]:ENABle {ON|OFF}
Function
Sets the channel recorder ON or OFF.
Example
:RECOrder2:ENABle ON
Enables CH2 recorder.
Command
:RECOrder[1|2|3|4]:ENABle?
Function
Queries the state of channel recorder.
Example
:RECOrder2:ENABle?
Returns the state of CH2 recorder, ON or OFF.
Command
:SEQUence[1|2]:CYCLEs {N|I}[,<value>]
Function
Sets the cycle number of sequence.
Description
{N|I} Sets cycle number as infinite (I) or specified
value (N, <value>).
Example
:SEQUence2:CYCLEs N,20
Sets the cycle number of sequence as 20.
Command
:SEQUence[1|2]:CYCLEs?
Function
Queries the cycle number of the sequence.
Example
:SEQUence2:CYCLEs?
Queries the cycle number of the sequence.
Returns to I or N, <value>.
Command
:SEQUence[1|2]:ENDState {OFF|LAST}
Function
Sets terminate state of sequence.
Description
{OFF|LAST} Output disabled (OFF): instrument
automatically disable output when output is
complete. The last group (LAST): instrument stays
at the output state of the last group when output is
complete.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPP-3323 and is the answer not in the manual?

GW Instek GPP-3323 Specifications

General IconGeneral
BrandGW Instek
ModelGPP-3323
CategoryPower Supply
LanguageEnglish

Related product manuals