Command
:SEQUence[1|2]:USB:LOAD <dest>
Function
Recalls the channel sequence output file saved in
the designated location from external storage.
<dest> indicates the designated location of
external storage.
Example
:SEQUence2:USB:LOAD USB:\R001.CSV
Recalls the CH2 sequence output file, R001.CSV,
saved in the external storage.
Command
:TRIGger:IN[:ENABle]
{D0|D1|D2|D3|D4},{ON|OFF}
Function
Enables or disables the trigger input finction of the
specified data line.
Example
:TRIGger:IN D0,ON
Enabled trigger input function of the D0 data line.
Command
:TRIGger:IN[:ENABle]?{D0|D1|D2|D3|D4}
Function
Queries the state of the trigger input function of the
specified data line.
Example
:TRIGger:IN? D0
Returns the state of the trigger input function of the
D0 data line.
Command
:TRIGger:IN:RESPonse{D0|D1|D2|D3|D4},{ON|
OFF||TOGGLE|POWER|CV|CC|CR|IND|SER|PAR }
Function
Sets the output response from the trigger input of
the specified data line.