Output Series mode (SER): when input signal of the
specified cable line meets the set triggering
condition, set CH1/CH2 in the series power mode.
Output Parallel mode (PAR): when input signal of
the specified cable line meets the set triggering
condition, set CH1/CH2 in the parallel power
mode.
Example
:TRIGger:IN:RESPonse D0,ON
Sets the output response from the trigger input of
the D0 data line as ON.
Note
IND|SER|PAR takes CH1/CH2 as the main body,
so it needs to run before executing this parameter:
TRIGger:IN:SOURce Dx, CH1, ON and
TRIGger:IN:SOURce Dx, CH2, ON.
Command
: TRIGger:IN:RESPonse? {D0|D1|D2|D3|D4}
Function
Queries the output response from the trigger input
of the specified data line.
Example
TRIGger:IN:RESPonse? D0
Returns the output reponse of the trigger input of
the queried D0 data line.
Command
: TRIGger:IN:SENSitivity
{D0|D1|D2|D3|D4},{LOW|MID|HIGH}
Function
Sets the trigger sensitivity from the trigger input of
the specified data line.
Description
LOW|MID|HIGH
Selecting lower level in trigger sensitivity will
avoid false press in noisy environment.
Example
: TRIGger:IN:SENSitivity D0,LOW
Sets the trigger sensitivity from the trigger input of
D0 data line as LOW.