REMOTE CONTROL
173
Description
POSItive|NEGAtive
Positive polarity (POSItive): when trigger condition
is met, it will output the actively specified output
signal.
Negative polarity (NEGAtive) when trigger
condition is met, it will invert and then output the
actively specified output signal.
Example
:TRIGger:OUT:POLArity D0,POSItive
Sets the polarity of the output signal from the
trigger input of D0 data line as POSItive.
Command
:TRIGger:OUT:POLArity? {D0|D1|D2|D3|D4}
Function
Queries the polarity of the output signal from the
trigger input of the specified data line.
Example
:TRIGger:OUT:POLArity? D0
Returns the polarity of the output signal from the
trigger input of D0 data line.
Command
:TRIGger:OUT:SOURce
{D0|D1|D2|D3|D4},{CH1|CH2|CH3|CH4}
Function
Sets the controlled channel from the trigger output
of the specified data line.
Description
CH1|CH2|CH3|CH4
Any of the channels, CH1, CH2, CH3, CH4 is
available for selection as controlled channel of
trigger output.
Example
:TRIGger:OUT:SOURce D0,CH1
Sets the controlled channel from the trigger output
of D0 data line as CH1.
Command
:TRIGger:OUT:SOURce?{D0|D1|D2|D3|D4}