EasyManua.ls Logo

GW Instek GPP-3323 - Page 175

GW Instek GPP-3323
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE CONTROL
175
Example
STATUS?
Command
:STATus:PRESet
Function
Clears the operation event enable registers, the
measurement event enable registers and the
questionable event register, The unit will then
return to the default settings status.
Example
:STATus:PRESet
Command
:STATus:OPERation[:EVENt]?
Function
Read the operation event register.
Example
:STATus:OPERation?
Reads the operation event register.
Command
:STATus:OPERation:CONDition?
Function
Read the operation condition status register.
Example
:STATus:OPERation:CONDition?
Read the contents of the operation condition
status register.
Command
:STATus:OPERation:ENABle <NRf>
Function
Programs the operation enable status register.
Description
<NRf>
8: CL (Current enable bit).
16: CLT (Current limit tripped enable
bit).
64: PSS (Power supply shutdown
enable bit).
Example
:STATus:OPERation:ENABle 64
Enable the power supply shutdown bit.

Table of Contents