REMOTE CONTROL
177
Command
:STATus:MEASurement:ENABle?
Function
Read the measurement enable status register.
Example
:STATus:MEASurement:ENABle?
Read the contents of the measurement enable
status register.
Command
:STATus:MEASurement:CONDition?
Function
Read the measurement condition status register.
Example
:STATus:MEASurement:CONDition?
Read the contents of the measurement condition
status register.
Command
:STATus:QUEStionable[:EVENt]?
Function
Read the questionable event status register.
Example
:STATus:QUEStionable?
Read the questionable event status register.
Command
:STATus:QUEStionable:CONDition?
Function
Read the questionable condition status register.
Example
:STATus:QUEStionable:CONDition?
Read the questionable condition status register.
Command
:STATus:QUEStionable:ENABle <NRf>
Function
Programs the questionable enable status register.
Description
<NRf>
256: CAL (Calibration summary enable
bit). Register is 16 bits. If <value> is
between 256 and 511, it is certainly
valid. If <value> is between 512 and
65,535, ensure Cal (bit8) is a valid
value.