REMOTE CONTROL
39
U
Query
The U query returns the current voltage limit.
U<CR>
ASCII
55 0D
HEX
Uuu<CR><LF>
Character
Description
U
Voltage limit unit
uu
Voltage limit value (2 characters, no
decimal)
U<CR>
U10<CR><LF>
Returns the current voltage limit.
10V
I
Query
The I query returns the current current limit.
I<CR>
ASCII
49 0D
HEX
Ii.ii<CR><LF>
Character
Description
I
current limit unit
i.ii
Current limit value (5 characters, 2
decimal places)
I<CR>
I1.500<CR><LF>
Returns the current current limit.
1.5A