25
Accessing the firewall
By default, the firewall uses the scheme access authentication mode. The username and password
are both admin.
Setting up the configuration environment and
configuring terminal parameters
CAUTION:
When you connect the console cable, identify the port marks and make sure you are connecting
the correct ports.
The serial ports on PCs do not support hot swapping. If the firewall has been powered on,
connect the serial console cable to the PC before connecting to the firewall, and when you
disconnect the cable, first disconnect from the firewall.
To access and manage the firewall locally, connect the serial console port or the micro USB console
port on the firewall to a configuration terminal (a PC for example). Only the micro USB console port is
available if you connect both the serial console port and micro USB console port.
To configure and manage the firewall through the serial console port or micro USB console port, you
must run a terminal emulator program, TeraTermPro or PuTTY, on your configuration terminal and
configure the following settings for the terminal. For more information about the terminal emulator
programs, see the user guides for these programs.
Bits per second—9600.
Data bits—8.
Stop bits—1.
Parity—None.
Flow control—None.
Starting the firewall
Pre-start checking
WARNING!
Locate the emergency power-off switch in the room before powering on the firewall so you can
quickly shut power off when an electrical accident occurs.
Before powering on the firewall, verify that the following conditions are met:
The power cord and grounding cable are correctly connected.
The power source specifications meet the firewall requirements.
The firewall is connected correctly to a configuration terminal (a PC for example). The
configuration terminal has been started and the parameters have been set correctly. For more
information, see "Setting up the configuration environment and configuring terminal
para
meters."
The interface modules (if any) are installed correctly.

Table of Contents

Other manuals for H3C SecPath F1020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C SecPath F1020 and is the answer not in the manual?

H3C SecPath F1020 Specifications

General IconGeneral
BrandH3C
ModelSecPath F1020
CategoryFirewall
LanguageEnglish

Related product manuals