33
Field Description
Swap Swap memory.
Displaying the operational status of power
modules
Use the display power command to display the operational status of power modules.
<Sysname> display power
Slot 1 Power 0 Status: Normal
Slot 1 Power 1 Status: Absent
Table 13 Output description
Field Description
Power Number of the power module.
Status
Power module state:
Normal—The power module is operating correctly.
Absent—The power module is not in position.
Abnormal—The power module has failed.
Displaying the temperature information of the
firewall
Use the display environment command to display the temperature information of the firewall.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Slot Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit S
hutdown-UpperLimit
1 inflow 1 36 0 60 70
NA
1 inflow 2 34 0 60 70
NA
1 outflow 1 42 0 60 70
NA
1 hotspot 1 62 0 80 92
NA
Table 14 Output description
Field Description
Slot Slot number of the interface module.

Table of Contents

Other manuals for H3C SecPath F5030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C SecPath F5030 and is the answer not in the manual?

H3C SecPath F5030 Specifications

General IconGeneral
BrandH3C
ModelSecPath F5030
CategoryFirewall
LanguageEnglish

Related product manuals