Organic Carbon, Total
© Hach Company, 2003. All rights reserved. Printed in the U.S.A. 3/04 1ed
Page 6 of 6 OrganicCarbonTotal_Other_High_DIR_Eng_Ody.fm
HACH COMPANY
WORLD HEADQUARTERS
Telephone: (970) 669-3050
FAX: (970) 669-2932
FOR TECHNICAL ASSISTANCE, PRICE INFORMATION AND ORDERING:
Call 800-227-4224
Contact the HACH office or distributor serving you.
www.hach.com techhelp@hach.com
In the U.S.A.
Outside the U.S.A.
On the Worldwide Web – ; E-mail –
toll-free
Required Reagents
Quantity Required
Description Per Test Unit Cat. No.
Total Organic Carbon Direct Method
High Range Test ’N Tube™ Reagent Set ......................................................................... 50 vials...............27604-45
Includes:
Acid Digestion Solution Vials, High Range TOC..........................1 ...................... 50/pkg
....................................*
Buffer Solution, Sulfate .....................................................................0.4 mL ............. 25 mL.....................452-33
Funnel, micro......................................................................................1....................... each....................25843-35
Indicator Ampules, High Range TOC.............................................1 ....................... 10/pkg............................ *
TOC Persulfate Powder Pillows ......................................................1 ....................... 50/pkg............................ *
pH Paper....................................................................................................1 ....................... 5/pkg.....................391-33
Water, organic-free....................................................................................3.0 mL ............. 500 mL...............26415-49
Required Apparatus
Adapter, 16-mm Cell ................................................................................1 ....................... each....................59457-00
COD Reactor, 115/230 VAC (U.S.A. and Canada)...............................1 ....................... each....................45600-00
COD Reactor, 115/230 VAC (Europe)....................................................1 ....................... each....................45600-02
Cylinder, graduated, 10-mL ....................................................................1 ....................... each........................508-38
Flask, Erlenmeyer, 50-mL ........................................................................1 ....................... each........................505-41
Magnetic Stirrer ........................................................................................1 ....................... each....................23436-00
Pipet, TenSette
®
, 0.1 to 1.0 mL ................................................................1 ....................... each....................19700-01
Pipet, TenSette
®
, 1.0 to 10.0 mL ..............................................................1 ....................... each....................19700-10
Pipet Tips, for 19700-01 TenSette
®
Pipet ...............................................2 ....................... 50/pkg...............21856-96
Pipet Tips, for 19700-10 TenSette
®
Pipet ...............................................2 ....................... 50/pkg...............21997-96
Safety Shield, laboratory bench ..............................................................1 ....................... each....................50030-00
Stir Bar, Magnetic......................................................................................1 ....................... each....................45315-00
Test Tube Rack...........................................................................................1–3 ................... each....................18641-00
Wipes, Disposable, Kimwipes
®
..............................................................1 ....................... 280/pkg.............20970-00
Required Standards
Potassium Acid Phthalate ................................................................................................. 500 g.......................315-34
TOC Standard Solution (KHP Standard, 1000-mg/L C) .............................................. 5/pkg.................27915-05
* Not sold separately.