Required Reagents
Quantity Required
Description Per Test Unit Cat. No.
Chloride Removal Cartridges (CRC).....................................................1 ....................... 25/pkg...............26618-25
Manganese III COD Reagent Vials, 20–1000 mg/L COD...................1 ....................... 25/pkg...............26234-25
Sulfuric Acid, concentrated, ACS...........................................................1 mL ................ 2.5 L .......................979-09
Water, deionized .......................................................................................varies .............. 4 L ..........................272-56
Required Apparatus
Adapter, 16-mm Cell ................................................................................1 ....................... each....................59457-00
Blender, 120 VAC ......................................................................................1....................... each....................26747-00
Blender Container, 50–250 mL................................................................1 ....................... 2/pkg.................26748-00
Cap, with inert Teflon liner, for mixing bottle......................................varies .............. 12/pkg...............24018-12
COD Reactor, 115–230 VAC, 50-60 Hz ............................................1....................... each....................45600-00
or COD Reactor, 230 VAC, 50 Hz..........................................................1 ....................... each....................45600-02
Forceps, extra fine point ..........................................................................1 ....................... each....................26696-00
Pipet, TenSette
®
, 1.0 to 10.0 mL ..............................................................1 ....................... each....................19700-10
Pipet Tips, for 19700-10 TenSette
®
Pipet ...............................................2 ....................... 50/pkg...............21997-96
Pipet, TenSette
®
, 0.1 to 1.0 mL ................................................................1 ....................... each....................19700-01
Pipet Tips, for 19700-01 TenSette
®
..........................................................2 ....................... 50/pkg...............21856-96
Safety Shield ..............................................................................................1....................... each....................50030-00
Test Tube Rack, COD................................................................................1 ....................... each....................18641-00
Vacuum Pretreatment Device (VPD) .....................................................1 ....................... each....................49000-00
Vacuum Pump, 1.2 CFM @ 60Hz. 27.2 Hg Max, 1/8 HP, UL listed .. 1 ....................... each....................28248-00
Vial, glass, for sample + acid...................................................................2 ....................... each....................24277-00
Required Standards
COD Standard Solution, 800-mg/L COD....................................................................... 200 mL...............26726-29
Potassium Acid Phthalate, ACS ....................................................................................... 500 g.......................315-34