Volatile Acids
Volatile Acids
VolatileAci_None_Other_ESR_Eng_Ody.fm Page 5 of 6
Required Reagents
Quantity Required
Description Per Test Unit Cat. No.
Volatile Acids Reagent Set (90 tests) .............................................................................................................22447-00
Includes:
(1) Ethylene Glycol.............................................................................3 mL ................ 1000 mL...............2039-53
(2) Ferric Chloride-Sulfuric Acid Solution .....................................20 mL .............. 1000 mL...............2042-53
(1) Hydroxylamine Hydrochloride Solution, 100-g/L .................1 mL ................ 100 mL...................818-42
(1) Sodium Hydroxide Standard Solution, 4.5 N ..........................4 mL ................ 1000 mL...............2040-53
(1) Sulfuric Acid Standard Solution, 19.2 N ...................................0.4 mL ............. 100 mL MDB.......2038-32
Water, deionized .......................................................................................20.5 mL ........... 4 L ..........................272-56
Required Apparatus
Centrifuge, 115 VAC, 60 Hz.....................................................................1 ....................... each....................26765-00
Centrifuge Tubes, 15-mL .........................................................................2 ....................... 10/pkg...............22787-39
Centrifuge Tube Caps ..............................................................................2....................... 20/pkg...............25852-20
Cylinder, graduated, 10-mL ....................................................................1 ....................... each........................508-38
Filter Paper, folded, 12.5-cm.................................................................... ......................... 100/pkg...............1894-57
Funnel, poly, 65-mm................................................................................. ......................... each......................1083-67
Hot Plate, 4-inch micro, 120 VAC...........................................................1 ....................... each....................12067-01
Hot Plate, 4-inch micro, 240 VAC...........................................................1 ....................... each....................12067-02
Pipet, Filler, safety bulb ...........................................................................1 ....................... each....................14651-00
Pipet, serological, 2-mL............................................................................1 ....................... each........................532-36
Pipet, volumetric, Class A, 0.50-mL.......................................................1 ....................... each....................14515-34
Pipet, volumetric, Class A, 10.00-mL.....................................................1....................... each....................14515-38
Sample Cells, 10-20-25 mL, w/cap.........................................................2....................... 6/pkg.................24019-06
Water Bath and Rack ................................................................................1....................... each......................1955-55
Required Standards
Volatile Acids Standard Solution,
10-mL Voluette
®
Ampule, 62,500-mg/L as HOAC................................................. 16/pkg...............14270-10