HB21FG* 
33
Issue  2010-12 
Rev.  
Ref1012S008V0
 
 
MODE OPERATION  WORKING CONDITION REMARK 
TEST1   
 (For testing 
the cooling 
capability) 
Under LOCK status, finish 
the following operation 
within 5 seconds: press 
four keys one by one, 
Function (A) - REF TEMP 
(D) - OK (B)- FRZ TEMP 
(C) and then press key 
Function (A) to enter 
Test1 mode
, the products 
will enter forced starting 
mode. 
1) compressor start working 
2) freezer fan motor start working   
3) cooling fan motor start working 
4) defrost heater closed 
5) air damper open 90° 
6) show T1/T1 at 
refrigerator/freezer setting of 
display board 
Mode TEST1 
continues until exit 
manual 
TEST2  
 
 (For testing 
the defrost 
system) 
Press key Function (A) 
under Test1 mode for 3 
seconds to enter Test2 
mode
,    then the product 
will enter forced defrosting 
mode  
1) compressor shutdown 
2) freezer/cooling fan motor 
shutdown 
3) defrost heater start working 
4) vertical girder heater shutdown 
5) air damper and it’s heater 
shutdown 
6) freezer/refrigerator setting 
display T2/T2 at display board 
When temperature 
around defrost 
sensor above 7 
degree, appliance 
will exit <Forced 
defrosting model> 
TEST3   
 (For testing 
assistant 
heater) 
Press key Function (A) 
under Test2 mode for 3 
seconds to enter Test3 
mode
, then the product will 
enter assistant heater 
inspection mode. 
1) compressor shutdown 
2) freezer/cooling fan motor 
shutdown 
3) defrost heater shutdown 
4) vertical girder heater start 
working 
5) air damper heater start working   
6) freezer/refrigerator setting 
display T3/T3 at display board 
exit the inspection 
program after 30 
minutes and back 
to normal 
TEST4 
Press key Function (A) 
under Test3 mode for 3 
seconds to enter Test4 
mode 
(No define function in Test4, it is for considering future 
use.) 
BACK TO 
NORMAL 
Under TEST4 mode, 
press key Function (A) for 
3 seconds ,the refrigerator 
will quit Test mode and 
back to normal
 
Function back to normal (compressor start to work 7 
minutes later)