11.
TROUBLE
SHOOTiNG
GUIDE
A
WARNING;
Before
checking
the
inside
of
the
FM-202
or
replacing
parts,
be
sure
to
disconnect
the
power
plug.
Failure
to
do
so
may
result
in
electric
shock.
The
unit
does
not
operate
when
the
power
switch
is
turned
on.
CHECK
CHECK
Is
the
power
cord
and/or
the
connection
plug
dis-
connected?
Connect
it.
Is
the
fuse
blown?
Investigate
why
the
fuse
blew
and
then
replace
the
fuse.
If
the
cause
can
not
be
determined,
replace
the
fuse.
If
the
fuse
blows
again,
send
the
unit
in
for
repair.
The
tip
does
not
heat
up.
•The
sensor
error
I
S
-f
|
is
dis¬
played.
CHECK
CHECK
Is
the
tip
inserted
properly?
Insert
the
tip
completely.
Is
the
connection
cord
and/or
the
heater/sensor
broken?
See
the
appropriate
section
of
this
manual
regarding
how
to
check
the
connection
cord
and/or
the
heater/sensor
for
breakage.
Solder
does
not
wet
the
tip.
CHECK
CHECK
Eggga
Is
the
tip
temperature
too
high?
Set
the
appropriate
temperature.
Is
the
tip
contaminated
with
oxide?
Remove
the
oxide
(see
“Tip
maintenance”
on
P.
12).
The
tip
temperature
is
too
high.
CHECK
ESim
CHECK
Eagfla
Is
the
connection
cord
broken?
See
“Checking
the
connection
cord
for
breakage"
on
P.
13.
Is
the
entered
tip
Identification
number
correct?
Enter
the
correct
value.
The
tip
temperature
is
too
low.
CHECK
CHECK
Is
the
tip
contaminated
with
oxide?
Remove
the
oxide
(see
“Tip
maintenance”
on
P.
12).
Is
the
entered
tip
identification
number
correct?
Enter
the
correct
value.
The
soidering
iron
error
ir-£l
is
dispiayed.
CHECK
EI3M1
Is
the
other
soldering
iron
connected?
Or
the
FM-2027
plug
disconnected?
Connect
the
FM-2027
or
Hakko
912
soldering
iron.