______________________________________________HARRIS
888-9058-001
WARNING: Disconnect and lockout AC primary power prior to servicing
85
STEP 33: Set Fault Log Filters. Fault Log filters (new as of eCDi™ firmware
revision 3.0.L) provide a way to block or limit the entries in the Fault Log.
Figure 3-17 shows the choices for the 3 categories of filters:
a. Faults
b.Warnings
c. Info
Figure 3-17 Fault Log Filters
• Selecting “None” (no filter) will allow all indications for the selected
category to be entered into the Fault Log.
• Selecting “Sum” will block all Summary indications in the selected
category. All other indications in that category will be entered into the
Fault Log.
• Selecting “All but Sum” (the most common selection) will block all
entries but the Summary indications for the selected category (i.e. only
summary indications will be entered into the Fault Log).
• Selecting “All” will block all Fault Log entries for that category. This
is most commonly used for the Info category since these are mostly
Status indications.
STEP 34: When all changes are made, press Submit and then press Back to return to the
main menu. Click on Meter Logging to access the screen in Figure 3-18.