3.15 AGC Module
VERIFICATION OF AGC OPERATION
1. Reduce transmitter power to 50%.
2, Set AGC MODE switch to OFF.
3. Raise transmitter power back to 100%.
4. Set AGC MODE switch to ON.
5. Verify AGC action reduces transmitter
power.
6. If AGC does not reduce transmitter
power, contact maintenance personnel
and have them set AGC per section 3.19
at the end of this chapter.
Figure 3-24. AGC Module
Table 3-2. AGC Module Controls and Indicators