ae.2. IF Printed Circuit Board 85-128-x
There are five (or possibly four) different revision levels of this board. Some differences
are (to be sorted out ...):
Revision Level P376 (SB-100)
R104 and R105 are 56
R106 is 22k
R110 is 330
Meter zero pot is 200
Revision Level 2 (SB-101, SB-102)
R104 and R105 are 56
R106 is 22k
R110 is 330
Meter zero pot is 200
Revision Level 4 (HW-101)
R104 and R105 are 47
R106 is 22k
R115 is 220
R110 is unused
Meter zero pot is 10K
Revision Level 5 (SB-102)
R104 and R105 are 56
R106 is 33k (this reduces the screen voltage on V3) – note: this change in value is recommended for all
models.
R110 is 510 (compensates for the change in R106 to permit zeroing the “S” Meter)
Meter zero pot is 200