10 6 HEIDENHAIN Technical Manual TNC 426, TNC 430
DSP ERROR F250 y Power module switches off during operation (external
operation error)
280 470-01,
280 472-01,
to
280 474-03
DSP ERROR F260 y Reserved
DSP ERROR F270 y Excessive angular deviation during alignment, Zn/Z1 tracks
do not match (encoder error)
DSP ERROR F280 y Motor is uncontrollable, at I
max
no expected rotary
movement (drive error)
DSP ERROR F290 y Error in 3-D probe/evaluation. No latching with L1 input
(G19/G26) (hardware problem)
DSP ERROR F2A0 y Incorrect ref. position found (hardware problem)
DSP ERROR F2B0 y Standstill detection (drive error)
DSP ERROR F2C0 y Actual current of motor exceeds limit (drive error)
DSP ERROR F2D0 y Status error in PWM chip (hardware problem)
DSP ERROR F2E0 y Incorrect rated voltage of motor (error in motor table)
DSP ERROR C110 y Motor type unknown, MP2200 (error in motor table or
MP2200)
280 474-04
DSP ERROR C120 y Reserved
DSP ERROR C130 y Reserved
DSP ERROR C140 y Number of pole pairs too large (error in motor table or
MP2230)
DSP ERROR C150 y ASM: field-defining current (error in motor table)
DSP ERROR C160 y Grating period of velocity encoder (error in motor table)
DSP ERROR C170 y ASM: Rotor time constant (error in motor table)
DSP ERROR C180 y Break/rated speed (error in motor table)
DSP ERROR C190 y Unknown drive type, MP2000
DSP ERROR C1A0 y Reserved
DSP ERROR C1B0 y Reserved
DSP ERROR C1C0 y Reserved
DSP ERROR C1D0 y Current sensor voltage (error in power module table)
DSP ERROR C1E0 y Peak current in power module (error in power module table)
DSP ERROR C1F0 y Current controller proportional factor too high
DSP ERROR C200 y Current controller integral factor too high
DSP ERROR C210 y Motor temperature
DSP ERROR C220 y Reserved
DSP ERROR C230 y Oscilloscope parameter is incorrect. Only for test purposes
(data processing error)
DSP ERROR C240 y Rated current of power module (error in power module)
DSP ERROR C250 y Rated current of motor (error in motor table)
DSP ERROR C260 y Peak current of motor (error in motor table)
Error message Cause of error, corrective action As of
NC SW