December 2001 List of Machine Parameters 4 – 49
4.3.14 Display and Operation
MP Function and input Software
version and
behavior
Page
MP7210 Programming station
Input: 0: Controlling and programming
1: Programming station with PLC active
2: Programming station with PLC inactive
CN123 6 – 324
MP7212 Power interrupted message
Input: 0: Acknowledge message with CE key
1: Message does not appear
PLC, CN123
RUN
6 – 327
MP7220 Block number increment for ISO programs
Input: 0 to 250
PLC, CN123
RUN
6 – 301
MP7224.0 Disabling soft keys for file types
Format: %xxxxxxxx
Input: 0: Do not disable
1: Disable
Bit 0 - HEIDENHAIN programs .H
Bit 1 – ISO programs .I
Bit 2 – Tool tables .T
Bit 3 – Datum tables .D
Bit 4 – Pallet tables .P
Bit 5 – Text files .A
Bit 6 – HELP files .HLP
Bit 7 – Point tables .PNT
PLC, CN123
RUN
6 – 300
MP7224.1 Protecting file types
Format: %xxxxxxxx
Input: 0: Do not protect
1: Protect
Bit 0 - HEIDENHAIN programs .H
Bit 1 – ISO programs .I
Bit 2 – Tool tables .T
Bit 3 – Datum tables .D
Bit 4 – Pallet tables .P
Bit 5 – Text files .A
Bit 6 – HELP files .HLP
Bit 7 – Point tables .PNT
6 – 300