EasyManua.ls Logo

HEIDENHAIN TNC 426 PB - Status of M Functions; Program Stop with M Functions

HEIDENHAIN TNC 426 PB
1135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 284 HEIDENHAIN Technical Manual TNC 426, TNC 430
Status of
Mfunctions
7
77
7 With Module 9060 you can ascertain the status of M functions M100 to
M199.
7
77
7 With Module 9061 the status of the non-modal M functions M94, M142,
M143 and M146 can be ascertained.
Module 9060 Status of M functions
Module 9060 can determine whether an M function between M100 and M199
is active.
Call:
PS B/W/D/K <Number of the M function (100 to 199)>
CM 9060
PL B/W/D <Status>
0: M function inactive
1: M function active
Error recognition:
Module 9061 Status of non-modal M functions
With module 9061 the status of the non-modal M functions M94, M142,
M143 and M146 can be interrogated. The status of the interrogated
M function is then set until the module is called again, even if the NC program
has finished.
Call:
PS B/W/D/K <Number of the M function (90 to 199)>
CM 9061
PL B/W/D <Status>
0: M function was not active
1: M function was active
Error recognition:
Program stop with
M functions
In the PROGRAM RUN, SINGLE BLOCK and the PROGRAM RUN, FULL
SEQUENCE operating modes the next NC block is not run until you have
reported execution of the M function:
7
77
7 Set M4092 in order to report the execution of the M function.
For special machines you can deselect the program stop (See "Special
Functions for Laser Cutting Machines on page 6 452).
7
77
7 Select the program stop with MP7440, bit 2.
Marker Value Meaning
M4203 0 Status was found
1 Error code in W1022
W1022 1 Invalid number of M function
Marker Value Meaning
M4203 0 Status was found
1 Error code in W1022
W1022 1 Invalid number of M function