December 2001 DSP Error Messages as of NC Software 280 476-01 10 15
C013 PWM frequency
error
n Entered PWM frequency
in MP2180 lies outside
the permissible input
range.
n Inform your service agency.
Check MP2180.
280 476-01
D000 DP RAM area
overlap
n An internal software
error has occurred.
n Inform your service agency.
Check software version.
280 476-01
D100 Software error n An internal software
error has occurred.
n Inform your service agency.
Check software version.
280 476-07
E001 Status NR1/NR2
not equal
n NR2 input incorrectly
connected.
n Internal software error.
n Inform your service agency.
Check the wiring.
Check software version.
280 476-01
E002 Status NE1/NE2
not equal
n NE2 input incorrectly
connected.
n Internal software error.
n Inform your service agency.
Check the wiring.
Check software version.
280 476-01
E003 PLC module 9169
illegal
n PLC Module 9169 in
safety-oriented software
(illegal).
n Internal software error.
n Inform your service agency.
Check the PLC program.
Check software version.
280 476-01
E006 Wrong RDY status
of spindle
n Cabling to inverter
defective.
n Spindle not connected
(spindle release relay).
n Inverter defective.
n Inform your service agency.
Check the inverter and
cabling.
280 476-01
E007 Wrong RDY status
of axes
n Cabling to inverter
defective.
n No axis connected (axis
release relay).
n Inverter defective.
n Inform your service agency.
Check the inverter and
cabling.
280 476-01
E008 SRG speed too
high
n Safe reduced rotational
velocity (SRG) was
exceeded.
n No standstill in safe
controlled stop (SBH)
operating mode.
n Inform your service agency. 280 476-01
E009 Incorrect gear
range
n Internal software error. n Inform your service agency.
Check software version.
280 476-01
E00A Safe machine
parameter erroneous
n CRC checksum does not
fit the entered safe MPs.
n Inform your service agency.
Check the safe machine
parameters.
280 476-01
E00B Cutout channels
test error
n Machine key depressed
(ZT.HR, ZT.MB, MT
signal).
n Inform your service agency.
Check the wiring X65, X66
(, X67).
Check the machine keys.
280 476-01
E00C Error in MP
transfer
n MP3210 or MP3510
incorrect.
n Software error MCU.
n Inform your service agency.
Check MP3210 and
MP3510.
Check software version.
280 476-01
Error message Cause Corrective action As of
NC SW

Table of Contents