14 Parameter Description
KRONOS 20 91
No. Name Signification
5413 MechEffMapOn
Level: 4
Range: 0..1
Page(s):
Activation of mechanical efficiency map
5430 GasValveELES80Or50
Level: 6
Range: 0..1
Page(s):
Selection of valve size (E-LES)
0 = E-LES 50
1 = E-LES 80
5460 ControlLambda-1On
Level: 4
Range: 0..1
Page(s):
Activation of lambda 1 control ((O2-sensor)
5530 AnalogIn3_Type
Level: 6
Range: 1..2
Page(s):
Signal type of analogue input 3
1 = 0..5 V
2 = 0..22,7 mA
5540 AnalogIn4_Type
Level: 6
Range: 0..1
Page(s):
Signal type of analogue input 4
0 = 0..65535 Digits
1 = 0..5 V
5600 CheckPowerSupplyOn
Level: 6
Range: 0..1
Page(s):
Activation of supply voltage monitoring
5705 StepperPositionerOn
Level: 4
Range: 0..1
Page(s):
Activation of positioner mode for stepper motor
(for test purposes)
5706 StpperPositionerMode
Level: 4
Range: 0..2
Page(s):
Selection of positioner mode
0 = direct position input
1 = triangle
2 = steps mode