Users Manual Henkovac 04-serie V2019
There is not enough gas in
the bag
The programmed gas level is too low
Increase the gas level value
The bag is not correctly positioned over the
gas outlets
The machine does not seal
The bag is not correctly positioned over the
sealing beam
The sealing wire is broken
The thermal safety of the power supply was
tripped
Wait until the safety resets, which can take
half an hour. Decrease the sealing time
The electrical contacts of the seal beam
have fouled
Remove the seal beam and clean the pins
and contacts with sand paper
The service symbol
appears when turn-
ing on the machine, indi-
cating the remaining pro-
duction hours or cycles
The service interval counters have reached
their maximum programmed values
To reset the service interval counters
after the oil change: Start machine
and while the display shows the hours
or cycles, press and hold the but-
ton
13.0 Recommended Spare Parts
Silicon T-profile (Length 5mtr)
Sealing Wire 3,5 x 0,3 (Convex, length 5mtr)
Sealing Wire Ø1,1 (Clean Cut, length 5mtr)
Teflon Tape (Length 5mtr)
Sealing Wire 5 x 0,2 (Flat)
Sealing Wire 8 x 0,2 (Flat)
Oil exhaust filter for 021m
3
/
h
Oil exhaust filter for 016m
3
/
h
Oil exhaust filter for 040m
3
/
h
Oil exhaust filter for 063 and 100m
3
/
h
Oil exhaust filter for 160 and 300m
3
/
h
Oil filter for 040, 063 and 100m
3
/
h
Oil filter for 160 and 300m
3
/
h
Oil ISO VG100 (1 Ltr) PRIVATE
Seal 8mm for transparent lid (Length 5mtr)
Silicone profile for stainless steel cover