EasyManua.ls Logo

HERMOS LFM LP Reader - Stream 2 (System Control)

Default Icon
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader 15.01.2019
Page 87 of 119
HERMOS AG
Gartenstrasse 19 Tel. +49(9279) 991-0
D-95490 Mistelgau Fax. +49(9279) 991-100
S1F16: OFFLINE ACKNOWLEDGE (reading device -> host)
Acknowledgement.
S1F16
<B[1] OFLACK>.
S1F17: REQUEST ON_LINE (host -> reading device, reply)
The reading device contains a request to change the communication state to "online".
S1F17 W (header only, no additional elements)
S1F18: ONLINE ACKNOWLEDGE (reading device -> host)
Acknowledgement
S1F18
<B[1] ONLACK>.
11.3.2 Stream 2 (system control)
S2F0: ABORT TRANSACTION (reading device <-> host)
This message is used instead of an expected reply to cancel an action.
S2F0 (header only, no additional elements)
S2F13: EQUIPMENT CONSTANT REQUEST (host -> reading device, reply)
The host requests an attribute (parameter) from the reading device.
S2F13 W
<L[1]
<U1[1] ECID>
>
S2F14: EQUIPMENT CONSTANT DATA (reading device -> host)
The reading device transmits the requested attribute (parameter) to the host.
S2F14
<L[1]
<U1[1] ECV>
>
S2F15: NEW EQUIPMENT CONSTANT SENT (host -> reading device, reply)
The host changes a reading device attribute (parameter).