Loading...
Protocol description ASCII, SECS/HSMS
Customer manual
Version 1.2
LFM LP Reader 15.01.2019
Page 91 of 119
HERMOS AG
Gartenstrasse 19 Tel. +49(9279) 991-0
D-95490 Mistelgau Fax. +49(9279) 991-100
11.3.4 Stream 5 (Exception handling)
S5F1: Alarm Report (reading device -> host, reply)
The reader reports an error to the host.
S5F1 W
<L[3]
<B[1] ALCD >
Alarmcodebyte
<B[1] ALID > Alarm-ID
<A[MAX 40] ALTX > Alarmtext
>
S5F2: Alarm Report confirmation (Host -> Lesegerät)
The host confirms the alarm message.
S5F2
<B[1] ACKC5 >
11.3.5 Stream 9 (system error)
S9F1: UNRECOGNIZED DEVICE ID (reading device -> host)
The device ID in the header of the message block does not correspond to the expected device ID
S9F1
<B[10] MHEAD >
S9F3: UNRECOGNIZED STREAM TYPE (reading device -> host)
The reading device does not recognise the stream type in the header of the message block.
S9F3
< B[10] MHEAD >
S9F5: UNRECOGNIZED FUNCTION TYPE (reading device-> host)
The reading device does not recognise the function number in the header of the message block.