S18F13: SUBSYSTEM COMMAND (host -> reading device, reply)
This message is used for requesting the subsystem specified in the TARGETID for executing a specific
procedure.
.
S18F13 ,W
<L,3
<TARGETID>
<SSCMD>
<L,n
1. <CPVAL>
n. <CPVALn>
>
>
S18F14: SUBSYSTEM COMMAND, ACKNOWLEDGE (Reading device-> host)
This message reports the result of the requested procedure.
S18F14 ,W
<L,3
<TARGETID>
<SSACK>
< L,1
<STATUSLISTE>
>
>