EasyManua.ls Logo

HETRONIC EX Series - Battery MINI-EX

HETRONIC EX Series
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ex manual Rev 0 - Oct 29, 2014 13
2.1.3 Battery MINI-EX-_ _ _
The explosion-proof battery type MINI-EX-_ _ _ is destined for the supply of portable,
intrinsically safe devices (e.g. radio transmitters) in hazardous areas. It has the duty to
restrict current to < 1,1 A in case of a short-circuit of the feeder clamp.
For the discharging process the battery is inserted in a corresponding battery compartment
of the operating device to be supplied. The battery should never be changed within the
hazardous area.
The spare battery can be taken into a hazardous area, but the operator has to keep it safe
at all times.
The battery must only be charged in HETRONIC battery chargers specially marked with EX,
type MINI UHC-2-AC-EX or MINI UHC-2-DC-EX and ONLY outside hazardous areas.
The battery housing consists of a black polyester moulding material. The non-antistatic
projected surface of the batteries is < 20 cm². The contacts of the EX-batteries are
interchanged to those of the standard batteries, in order to avoid operation of the intrinsically
safe device with wrong batteries.
Rechargeable battery packs are hazardous waste! Use a specialist
disposal company for recycling or disposal! Defective battery packs can
also be disposed of directly through HETRONIC!

Related product manuals